DTI 1320 Series

The DTI 1320 is one of a family of low-cost solutions to the implementation of field devices that require NTCIP conformant communication. The small size and powerful performance of the DTI 1320 controller make it the perfect engine to control signs, traffic count systems, weather stations, cameras or any custom application where NTCIP communication is required.

Four serial ports are provided (2 ports are jumper- selectable to be RS232 or RS485), as well as digital inputs and outputs and analog inputs. The module is provided with NTCIP communications built in, so the only custom development required is the interfacing of the module to the applicable field sensor or output device. An Ethernet port provides a powerful optional connection for high speed communication, and an on board temperature sensor is provided as standard.

The DTI 1320 incorporates a “flash disk” (8 MB standard) for storage of any logging data or other information. This makes it a perfect choice for applications where on board data storage is required.

DTI 1320 Features:

DTI 1320

  • Low cost NTCIP solution
  • Small size, powerful performance
  • Four serial ports are provided
  • Watchdog supervision is standard
  • Includes a time clock module
  • Battery backup maintains system memory and real time clock
  • Ethernet port included
  • 8 MB Flash disk for on board data storage

 

1320 Resources

Cable Connector (Rev D)
Component Layout (Rev D)
Jumper Settings (Rev D)
Mechanical Layout (Rev D)

 

HARDWARE SPECIFICATION

Module Size 5.7” x 4.8” x .6”, 144mm x 122mm x 18mm (Standard)
(overall, including connectors): 5.7” x 4.8” x .9, 144mm x 122mm x 24mm (Ethernet)
Attachment: Qty. 4, 0.156” (4mm) holes
Operating Temp: -40°C to +74°C (-40°F to +165°F)
Humidity: 5-95% non-condensing
Power Requirement: 8-30 V AC or DC – Less than 100mA
Digital I/O 8 inputs , 4 outputs
Analog Inputs 4 Inputs – 12 bit accuracy
Processor Speed: 22.1 MHz
SRAM: 512 kB (standard)
Flash: 512 kB (standard)
8 MB serial (data storage) Bigger memory sizes optional.
Serial Ports: 4 Total (2 – RS232 Full Hardware Flow Control, 2 – RS232 Full Hardware Flow Control or 4 Wire RS485)
Watchdog Supervisor: Yes
Time/date Clock: Yes
Battery Back up: Yes
Temperature Sensor: Yes
LED: 4 – Heartbeat, Rx, Tx, Diagnostics
Switches: Reset, 8 position DIP
Ethernet (Optional) 10 BaseT with 2 diagnostic LED’s

 

SOFTWARE SPECIFICATION

PROTOCOL STACKS SUPPORTED
Direct Connect (RS-232):
Data Objects > SNMP > Null > PMPP > RS-232 > Twisted Pair
Direct Connect (RS-485):
Data Objects > SNMP > Null > PMPP > RS-485 > Twisted Pair
Dial Up :
Data Objects > SNMP > Null > PMPP > V Series Modem > Telephone Co
Data Objects > SNMP > UDP/IP > PPP > V Series Modem > Telephone Co
Ethernet (optional):
Data Objects > SNMP > TCP/IP > Ethernet
Data Objects > SNMP > UDP/IP > Ethernet

STANDARD MASTER OID TABLES
1201 – Global Objects
1203 – Dynamic Message Signs
1204 – Environmental Sensor Systems
1205 – CCTV Camera Control
1209 – Transportation System Sensors
Custom Conformance Group Con?guration available

PROGRAMMING
Custom device drivers programmed in “C”, running as a separate task in a real time multi-tasking operating system.

OPTIONS
Training, Application Assistance, Telephone Support, Upgrades and Enhancements

ORDERING INFORMATION
DTI 1320 – Base Controller
DTI 1321 – Base Controller with optional 10 Base-T Ethernet